Solenoid valve failure and exclusion

1, the electromagnetic valves do not work after power -

     Check the power wiring is bad → re-wiring and connectors to connect

     Check power supply voltage is within ± scope of work - → tone caused by the scope of its normal position

     Coil is re-welding Sealing-off →

     → replace the coil short-circuit coil

     Working pressure is inappropriate to adjust the pressure → → or replacement of the electromagnetic proportional valve

     Fluid temperature is too high → commensurate with the electromagnetic valve replacement

     Impurities so that the main solenoid valve spool and the moving core stuck → cleaning and, if seal is damaged seals should be replaced and installed filters

     Too much liquid viscosity, the frequency is too high and life has come to replace the product →

2, the electromagnetic valve can not be closed

     Moving the main spool or iron core of the seal is damaged seals replaced →

     Fluid temperature, viscosity is too high to replace their counterparts in the electromagnetic valve →

     Impurities into the solenoid valve spool or moving core capacity washing →

     Spring has come to life or deformation → replace

     Orifice hole to plug → timely clean balance

     Operating frequency is too high or life has come to re-election of products or product →

3, other conditions

     → check inside the leak seals is damaged, whether the assembly of non-performing spring

     Outer → connections loose or leaking seals have been broken → screws or replace seals

     Power when the solid pieces of noise → head loose, tighten. Voltage fluctuation is not permitted within the scope, adjusting the voltage. Core Pull-surface impurities or uneven, timely cleaning or replacement. ball valve Trunnion Mounted Ball Valve Floating Ball Valve Top Entry Ball Valve Three way ball valve V Type Ball Valve